S001 | Delivery and return circulation group for primary circuits of solar systems
Delivery and return circulation group for primary circuits of solar systems. The flow goes from the solar panel to the boiler. It includes: interception ball valves with thermometers, pump for solar plants, air vent group, 6 bar safety valve, filling and drain taps to wash the system before filling, 0-12 lt/min flowmeter to regulate the flow, antigravity check valve, gauge, thermalproof shell.
Technical datasheet
Instruction Sheet
Declaration of Conformity
S002 | Return circulation group for primary circuits of solar systems
Return circulation group for primary circuits of solar systems. The flow goes from the solar panel to the boiler. It includes: interception ball valves with thermometers, pump for solar plants, 6 bar safety valve, filling and drain taps to wash the system before filling, 0-12 lt/min flowmeter to regulate the flow, anti-gravity check valve, gauge, thermal-proof shell.
Technical datasheet
Instruction Sheet
Declaration of Conformity
TAS003 | Delivery and return solar station for primary circuits of solar systems – With integrated controller
Delivery and return solar station for primary circuits of solar systems with integrated controller. The flow goes from the solar panel to the boiler. It includes:
interception ball valves with thermometers, pump for solar plants, air vent group, 6 bar safety valve, filling and drain taps to wash the system before filling, 0-12 lt/min
flowmeter to regulate the flow, antigravity check valve, gauge, thermal-proof shell. It can
be integrated with the microprocessor units art. S303 or art. S305.
Technical datasheet
Instruction Sheet
Declaration of Conformity
S004 | Return circulation group for primary circuits of solar systems
Return circulation group for primary circuits of solar systems with integrated controller. The flow goes from the solar panel to the boiler. It includes: interception ball
valves, pump for solar plants, air vent group, 6 bar safety valve, filling and drain taps to wash the system before filling, 0-12 lt/min flowmeter to regulate the flow, antigravity
check valve, gauge, thermal-proof shell. It can be integrated with the microprocessor
units art. S303 or art. S305.
Technical datasheet
Instruction Sheet
Declaration of Conformity
TAS001 | Delivery and return circulation group for primary circuits of solar systems
Delivery and return circulation group for primary circuits of solar systems. The flow goes from the solar panel to the boiler. It includes: interception ball valves with thermometers, pump for solar plants, Wilo Para 15/1-7 or Grundfos 15/6, air vent group, 6 bar safety valve, filling and drain taps to wash the system before filling, 0-12 lt/min flowmeter to regulate the flow, antigravity check valve, gauge, thermal-proof shell.
Technical datasheet
Instruction Sheet
Declaration of Conformity