Art. | Voltage | Code | |
787 | 230 volt | 82787BI53 | 1 |
787 | 24 volt AC | 82787BI54 | 1 |
787 | Electric servomotor
3-point rotating electric servomotor (modulating and bidirectional). It is installed on the mixing valve by means of a screw. Rotation angle 90°. The servomotor can also work manually by means of its switch. For the proper functioning and connection please refer to the instructions in the technical sheet.
Codes and dimensions
Related products
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Declaration of Conformity
P310 | Safety thermostat
Safety thermostat. Suitable for underfloor systems with high temperature boiler supply. It stops the pump when reaching 50˚C.
Technical datasheet
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity