Art. | Head connection | Outlets | Code | Fitting thread | Length total collector | |
K009 | 1" | 2 | 87K009PG06 | 3/4” EK. | 1 | 104 mm |
K009 | 1" | 3 | 87K009PH06 | 3/4” EK. | 1 | 154 mm |
K009 | 1" | 4 | 87K009PJ06 | 3/4” EK. | 1 | 204 mm |
K009 | 1" | 5 | 87K009PQ06 | 3/4” EK. | 1 | 254 mm |
K009 | 1" | 6 | 87K009PK06 | 3/4” EK. | 1 | 304 mm |
K009 | 1" | 7 | 87K009PR06 | 3/4” EK. | 1 | 354 mm |
K009 | 1" | 8 | 87K009PL06 | 3/4” EK. | 1 | 404 mm |
K009 | 1" | 9 | 87K009PS06 | 3/4” EK. | 1 | 454 mm |
K009 | 1" | 10 | 87K009PM06 | 3/4” EK. | 1 | 504 mm |
K009 | 1" | 11 | 87K009PT06 | 3/4” EK. | 1 | 554 mm |
K009 | 1" | 12 | 87K009PU06 | 3/4” EK. | 1 | 604 mm |
K009 | 1" | 13 | 87K009PV06 | 3/4” EK. | 1 | 654 mm |
K009 | 1" | 14 | 87K009PW06 | 3/4” EK. | 1 | 704 mm |
K010 | 1" | 2 | 87K010PG06 | M24x1,5 | 1 | 104 mm |
K010 | 1" | 3 | 87K010PH06 | M24x1,5 | 1 | 154 mm |
K010 | 1" | 4 | 87K010PJ06 | M24x1,5 | 1 | 204 mm |
K010 | 1" | 5 | 87K010PQ06 | M24x1,5 | 1 | 254 mm |
K010 | 1" | 6 | 87K010PK06 | M24x1,5 | 1 | 304 mm |
K010 | 1" | 7 | 87K010PR06 | M24x1,5 | 1 | 354 mm |
K010 | 1" | 8 | 87K010PL06 | M24x1,5 | 1 | 404 mm |
K010 | 1" | 9 | 87K010PS06 | M24x1,5 | 1 | 454 mm |
K010 | 1" | 10 | 87K010PM06 | M24x1,5 | 1 | 504 mm |
K010 | 1" | 11 | 87K010PT06 | M24x1,5 | 1 | 554 mm |
K010 | 1" | 12 | 87K010PU06 | M24x1,5 | 1 | 604 mm |
K010 | 1" | 13 | 87K010PV06 | M24x1,5 | 1 | 654 mm |
K010 | 1" | 14 | 87K010PW06 | M24x1,5 | 1 | 704 mm |
K009 – K010 | Manifolds unit with adjustment lockshields and valves with thermostatic option
Manifolds unit with adjustment lockshields and valves with thermostatic option. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Brackets with anti-vibration supports (art.208).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose electrothermic actuators with 28×1,5 connection thread.
Codes and dimensions
Related products
K060 | Pre-assembled for radiant panel systems with low temperature circuits
Pre-assembled group with box. For radiant panel systems with low temperature circuits, high temperature supply, fixed point mixing unit. It is supplied with pump P328 (Grundfos UPM3 Hybrid) and safety thermostat P310 installed in the box. Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
K025 – K026 | Manifolds unit with memory flowmeters and valves with thermostatic option – With angle ball valve
Manifolds unit with memory flowmeters and valves with thermostatic option. It includes: 2 ball valves (art. 225), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1” male/female intermediate fittings with revolving connection (art.204). Conical sealing gasket. Art.204 can be assembled between manifold and ball valve. 2 3/8” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
K025 – K026 | Manifolds unit with memory flowmeters and valves with thermostatic option – With straight ball valve
Manifolds unit with memory flowmeters and valves with thermostatic option. It includes: 2 ball valves (art. 215), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1” male/female intermediate fittings with revolving connection (art.204). Conical sealing gasket. Art.204 can be assembled between manifold and ball valve. 2 3/8” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
A1K013 | Pre-assembled group for radiant panel systems with low temperature circuits
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point three-way mixing system with differential maximum pressure valve and flow meter. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330.
1005 – 1006 | Delivery manifold with micrometric regulation lockshields
Delivery manifold with micrometric regulation lockshields. Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Technical datasheet
Declaration of Conformity
A3K013 | Pre-assembled group for radiant panel systems with low temperature circuits – Complete with thermostatic head
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point two-way mixing system. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330 (page 182).
177 | Insulators for 1” and 1”1/4 manifolds
Insulators for 1” and 1”1/4 manifolds. For manifolds 1” up to 12 outlets, for manifolds 1”1/4 up to 15 outlets. The insulators can be cut, to insulate the manifolds carrying a lower outlet number. Holes on both sides with 50 mm interaxe.
K031 – K032 | Manifolds unit with memory flowmeters and valves with thermostatic option – With straight valve
Manifolds unit with memory flowmeters and valves with thermostatic option.
It includes: 2 ball valves (art.215), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1/2” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity